Features
- Enhanced Ease of Use: The AHP300 offers value-added features for intra-hospital and inter-hospital transport.
- Quick Start Ventilation - Featuring programmable presets, the AHP300 allows trained caregivers to rapidly recall up to 5 saved ventilation protocols.
- Long Battery Life - Up to 7.5 hours on internal battery, with auxiliary battery capability for up to 21 hours of battery life.
- Quick Start Ventilation - Featuring programmable presets, the AHP300 allows trained caregivers to rapidly recall up to 5 saved ventilation protocols.
- Long Battery Life - Up to 7.5 hours on internal battery, with auxiliary battery capability for up to 21 hours of battery life.
- Oxygen Conserve Mode - Allows the use of low pressure sources (oxygen concentrator, liquid oxygen, etc.) to extend available oxygen.
- Multi-Environment Capability: For everyday transport or evacuation from extreme environments, the AHP300 has you covered. It features rugged shock and vibration resistance, and IPX22 water resistance
- Low Cost of Ownership: Simple preventive maintenance schedule along with low-cost battery and repair parts result in significant savings and lower cost of ownership than comparative broad- featured ventilators.
- Specifications :
- Patient Range: Infant/Pediatric (≥5 kg) - Adult
- Modes: Programmable Quick Start Presets (Pressure or Volume) A/CMV (Pressure or Volume) SIMV CPAP. Bi-PAP (can be programmed in custom mode)
- Tidal Volume: 40 to 2,000 ml
- RR (Respiratory Rate): 0,5 to 60 b/min
- I Time (Inspiratory Time): 0.5 to 2.0 sec.
- PEEP/CPAP: 0 to 25 cmH2O/0 to 25 mbar.
- PS (Pressure Support)++: 0 to 25 cmH2O/0 to 25 mbar*
- Flow: 5 to 60 L/min (flows ≥ 80 LPM in PS Mode, CPAP and demand flows)
- Pressure Control (Target Pressure): 15 to 55 cmH2O/15 to 55 mbar.
- Ptrig (Sensitivity): -5 to -1 cmH2O/-5 to -1 mbar.
- Manual Inflation: 2 second maximum
- FiO2: .21 to 1.00
- Maximum I Time: 2 seconds
- Flow Wave Pattern: Square or descending
- Auto Lock Function: ON / OFF
- Remote Alarm Option: Normally Open/Closed
- *PEEP + PS cannot exceed 25 cmH2O/mbar Operating Humidity 5 to 95% non-condensing. Based on mode selected
- Monitored Parameters: Paw (Peak, Base), Delivered Tidal Volume, Spontaneous Breath Count, Integrated Battery Level, External Battery Level - When Attached
- Calculated Parameters: I:E Ratio, Flow rate, FiO2
- Power Requirements: 110- 240 VAC, 50/60 Hz, max. 1A. / 11-15 VDC, max. 5A
AverMed offers a complete line of Automatic Transport Ventilators - AutoVent 2000/3000 by Allied Healthcare Products.- If you are unable to find the product you need, please
- contact our customer service department.
|
|
 |
 |
 |
 |
|
 |


|